LC1D18F7 - Contator Tripolar 18A 110VCA 1NA+1NF - Schneider Electric
LC1D18F7
0 Opiniões
Disponibilidade: Imediata
Simulador de Frete
- Calcular freteDescrição Geral
LINHA | TESYS TESYS DECA |
---|---|
NOME DO PRODUTO | TESYS D TESYS DECA |
TIPO DE PRODUTO OU COMPONENTE | CONTATOR |
NOME ABREVIADO DO DISPOSITIVO | LC1D |
APLICAÇÃO DO CONTATOR | CONTROLE DO MOTOR CARGA RESISTIVA |
CATEGORIA DE USO | CA-1 CA-4 CA-3 AC-3E |
DESCRIÇÃO DE POLOS | 3P |
POWER POLE CONTACT COMPOSITION | 3 NA |
[UE] TENSÃO DE OPERAÇÃO NOMINAL | CIRCUITO DE POTÊNCIA: <= 690 V CA 25...400 HZ CIRCUITO DE POTÊNCIA: <= 300 V CC |
[IE] CORRENTE NOMINAL DE OPERAÇÃO | 18 A (A < 60 &DEG;C) A <= 440 V CA CA-3 PARA CIRCUITO DE POTÊNCIA 32 A (A < 60 &DEG;C) A <= 440 V CA CA-1 PARA CIRCUITO DE POTÊNCIA 18 A (A < 60 &DEG;C) A <= 440 V CA AC-3E PARA CIRCUITO DE POTÊNCIA |
ALIMENTAÇÃO DO MOTOR KW | 4 KW A 220..0,230 V CA 50/60 HZ (CA-3) 7,5 KW A 380..0,400 V CA 50/60 HZ (CA-3) 9 KW A 415...440 V CA 50/60 HZ (CA-3) 10 KW A 500 V CA 50/60 HZ (CA-3) 10 KW A 660...690 V CA 50/60 HZ (CA-3) 4 KW A 400 V CA 50/60 HZ (CA-4) 4 KW A 220..0,230 V CA 50/60 HZ (AC-3E) 7,5 KW A 380..0,400 V CA 50/60 HZ (AC-3E) 9 KW A 415...440 V CA 50/60 HZ (AC-3E) 10 KW A 500 V CA 50/60 HZ (AC-3E) 10 KW A 660...690 V CA 50/60 HZ (AC-3E) |
MOTOR POWER HP (UL / CSA) | 1 HP A 115 V CA 50/60 HZ OF MONOFÁSICOMOTORES 3 HP A 230/240 V CA 50/60 HZ OF MONOFÁSICOMOTORES 5 HP A 200/208 V CA 50/60 HZ OF TRIFÁSICO MOTORES 5 HP A 230/240 V CA 50/60 HZ OF TRIFÁSICO MOTORES 10 HP A 460/480 V CA 50/60 HZ OF TRIFÁSICO MOTORES 15 HP A 575/600 V CA 50/60 HZ OF TRIFÁSICO MOTORES |
TIPO DO CIRCUITO DE CONTROLE | CA A 50/60 HZ |
[UC] TENSÃO DO CIRCUITO DE CONTROLE | 110 V CA 50/60 HZ |
CONTATO AUXILIAR | 1 NA + 1 NF |
[UIMP] TENSÃO NOMINAL SUPORTÁVEL DE IMPULSO | 6 KV CONFORME IEC 60947 |
CATEGORIA DE SOBRETENSÃO | III |
[ITH] CORRENTE TÉRMICA AO AR LIVRE CONVENCIONAL | 10 A (A 60 &DEG;C) PARA CIRCUITO DE SINALIZAÇÃO 32 A (A 60 &DEG;C) PARA CIRCUITO DE POTÊNCIA |
CAPACIDADE DE FECHAMENTO NOMINAL IRMS | 140 A CA PARA CIRCUITO DE SINALIZAÇÃO CONFORME IEC 60947-5-1 250 A CC PARA CIRCUITO DE SINALIZAÇÃO CONFORME IEC 60947-5-1 300 A A 440 V PARA CIRCUITO DE POTÊNCIA CONFORME IEC 60947 |
CAPACIDADE DE CORTE NOMINAL | 300 A A 440 V OF CIRCUITO DE POTÊNCIA PARA IEC 60947 |
[ICW] CORRENTE NOMINAL DE CURTA DURAÇÃO ADMISSÍVEL | 145 A 40 &DEG;C - 10 S PARA CIRCUITO DE POTÊNCIA 240 A 40 &DEG;C - 1 S PARA CIRCUITO DE POTÊNCIA 40 A 40 &DEG;C - 10 MÍN PARA CIRCUITO DE POTÊNCIA 84 A 40 &DEG;C - 1 MÍN PARA CIRCUITO DE POTÊNCIA 100 A - 1 S PARA CIRCUITO DE SINALIZAÇÃO 120 A - 500 MS PARA CIRCUITO DE SINALIZAÇÃO 140 A - 100 MS PARA CIRCUITO DE SINALIZAÇÃO |
CLASSIFICAÇÃO DO FUSÍVEL ASSOCIADO | 10 A GG PARA CIRCUITO DE SINALIZAÇÃO CONFORME IEC 60947-5-1 50 A GG A <= 690 V COORDENAÇÃO TIPO 1 PARA CIRCUITO DE POTÊNCIA 35 A GG A <= 690 V COORDENAÇÃO TIPO 2 PARA CIRCUITO DE POTÊNCIA |
IMPEDÂNCIA MÉDIA | 2,5 MOHM - ITH 32 A 50 HZ OF CIRCUITO DE POTÊNCIA |
[UI] TENSÃO DE ISOLAMENTO NOMINAL | CIRCUITO DE POTÊNCIA: 690 V PARA IEC 60947-4-1 CIRCUITO DE POTÊNCIA: 600 V CSA CERTIFICADO CIRCUITO DE POTÊNCIA: 600 V UL CERTIFICADO CIRCUITO DE SINALIZAÇÃO: 690 V PARA IEC 60947-1 CIRCUITO DE SINALIZAÇÃO: 600 V CSA CERTIFICADO CIRCUITO DE SINALIZAÇÃO: 600 V UL CERTIFICADO |
DURABILIDADE LÂMPADA | 1,65 MCICLOS 18 A CA-3 NO UE <= 440 V 1 MCICLOS 32 A CA-1 NO UE <= 440 V 1,65 MCICLOS 18 A AC-3E NO UE <= 440 V |
DISSIPAÇÃO DE ALIMENTAÇÃO POR POLO | 2,5 W CA-1 0,8 W CA-3 0,8 W AC-3E |
FRONT COVER | COM |
SUPORTE DE MONTAGEM | PLACA CALHA |
NORMAS | CSA C22.2 NO 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1 |
CERTIFICAÇÕES DO PRODUTO | GL RINA UL CCC DNV LROS (LLOYDS REGISTER OF SHIPPING) CSA GOST BV UKCA |
CONEXÕES - TERMINAIS | CIRCUITO DE CONTROLE: TERMINAIS DE PARAFUSO 1 CABO(S)1&HELLIP;4 MM&SUP2;FLEXÍVEL SEM PONTA DO CABO CIRCUITO DE CONTROLE: TERMINAIS DE PARAFUSO 2 CABO(S)1&HELLIP;4 MM&SUP2;FLEXÍVEL SEM PONTA DO CABO CIRCUITO DE CONTROLE: TERMINAIS DE PARAFUSO 1 CABO(S)1&HELLIP;4 MM&SUP2;FLEXÍVEL COM PONTA DO CABO CIRCUITO DE CONTROLE: TERMINAIS DE PARAFUSO 2 CABO(S)1&HELLIP;2,5 MM&SUP2;FLEXÍVEL COM PONTA DO CABO CIRCUITO DE CONTROLE: TERMINAIS DE PARAFUSO 1 CABO(S)1&HELLIP;4 MM&SUP2;SÓLIDO SEM PONTA DO CABO CIRCUITO DE CONTROLE: TERMINAIS DE PARAFUSO 2 CABO(S)1&HELLIP;4 MM&SUP2;SÓLIDO SEM PONTA DO CABO CIRCUITO DE POTÊNCIA: TERMINAIS DE PARAFUSO 1 CABO(S)1,5&HELLIP;6 MM&SUP2;FLEXÍVEL SEM PONTA DO CABO CIRCUITO DE POTÊNCIA: TERMINAIS DE PARAFUSO 2 CABO(S)1,5&HELLIP;6 MM&SUP2;FLEXÍVEL SEM PONTA DO CABO CIRCUITO DE POTÊNCIA: TERMINAIS DE PARAFUSO 1 CABO(S)1&HELLIP;6 MM&SUP2;FLEXÍVEL COM PONTA DO CABO CIRCUITO DE POTÊNCIA: TERMINAIS DE PARAFUSO 2 CABO(S)1&HELLIP;4 MM&SUP2;FLEXÍVEL COM PONTA DO CABO CIRCUITO DE POTÊNCIA: TERMINAIS DE PARAFUSO 1 CABO(S)1,5&HELLIP;6 MM&SUP2;SÓLIDO SEM PONTA DO CABO CIRCUITO DE POTÊNCIA: TERMINAIS DE PARAFUSO 2 CABO(S)1,5&HELLIP;6 MM&SUP2;SÓLIDO SEM PONTA DO CABO |
TORQUE DE APERTO | CIRCUITO DE POTÊNCIA: 1,7 N.M - LIGAR TERMINAIS DE PARAFUSO - COM CHAVE DE FENDA PLANO DE &OSLASH; 6 MM CIRCUITO DE POTÊNCIA: 1,7 N.M - LIGAR TERMINAIS DE PARAFUSO - COM CHAVE DE FENDA PHILIPS N&ORDM; 2 CIRCUITO DE CONTROLE: 1,7 N.M - LIGAR TERMINAIS DE PARAFUSO - COM CHAVE DE FENDA PLANO DE &OSLASH; 6 MM CIRCUITO DE CONTROLE: 1,7 N.M - LIGAR TERMINAIS DE PARAFUSO - COM CHAVE DE FENDA PHILIPS N&ORDM; 2 CIRCUITO DE CONTROLE: 1,7 N.M - LIGAR TERMINAIS DE PARAFUSO - COM CHAVE DE FENDA POZIDRIV N 2 CIRCUITO DE POTÊNCIA: 2,5 N.M - LIGAR TERMINAIS DE PARAFUSO - COM CHAVE DE FENDA POZIDRIV N 2 |
TEMPO DE OPERAÇÃO | 12...22 MS FECHAMENTO 4...19 MS ABERTURA |
NÍVEL DE FIABILIDADE DE SEGURANÇA | B10D = 1369863 CICLOS CONTATOR COM CARGA NOMINAL PARA EN/ISO 13849-1 B10D = 20000000 CICLOS CONTATOR COM CARGA MECÂNICA PARA EN/ISO 13849-1 |
DURABILIDADE MECÂNICA | 15 MCICLOS |
MAXIMUM OPERATING RATE | 3600 CIC/H 60 &DEG;C |
TECNOLOGIA DA BOBINA | SEM MÓDULO SUPRESSOR INTEGRADO |
---|---|
LIMITES DE TENSÃO DE CIRCUITO DE CONTROLE | 0,3...0,6 UC -40&HELLIP;70 &DEG;C SAÍDA CA 50/60 HZ 0,8...1.1 UC -40&HELLIP;60 &DEG;C FUNCIONAMENTO CA 50 HZ 0,85...1.1 UC -40&HELLIP;60 &DEG;C FUNCIONAMENTO CA 60 HZ 1...1.1 UC 60&HELLIP;70 &DEG;C FUNCIONAMENTO CA 50/60 HZ |
POTÊNCIA DE IRRUPÇÃO EM VA | 70 VA 60 HZ COS PHI 0,75 (A 20 &DEG;C) 70 VA 50 HZ COS PHI 0,75 (A 20 &DEG;C) |
CONSUMO DE POTÊNCIA DE MANUTENÇÃO EM VA | 7,5 VA 60 HZ COS PHI 0,3 (A 20 &DEG;C) 7 VA 50 HZ COS PHI 0,3 (A 20 &DEG;C) |
DISSIPAÇÃO DE CALOR | 2&HELLIP;3 W A 50/60 HZ |
TIPO DE CONTATOS AUXILIARES | TIPO COM LIGAÇÃO MECÂNICA 1 NA + 1 NF PARA IEC 60947-5-1 TIPO CONTATO DE ESPELHO 1 NF PARA IEC 60947-4-1 |
FREQUÊNCIA DO CIRCUITO DE SINALIZAÇÃO | 25..0,400 HZ |
CORRENTE DE COMUTAÇÃO MÍNIMA | 5 MA PARA CIRCUITO DE SINALIZAÇÃO |
TENSÃO DE COMUTAÇÃO MÍNIMA | 17 V PARA CIRCUITO DE SINALIZAÇÃO |
TEMPO NÃO SOBREPOSTO | 1,5 MS NA DESENERGIZAÇÃO ENTRE CONTATO NA E NF 1,5 MS NA ENERGIZAÇÃO ENTRE CONTATO NA E NF |
RESISTÊNCIA DE ISOLAMENTO | > 10 MOHM PARA CIRCUITO DE SINALIZAÇÃO |